Meldorf WWTP, Germany

 

 

 

Home
The Technology
Applications
Case Studies
Technical Papers
Project Process
Process Questionnaire
Contact Us


Combatting of foaming formation in digester by ultrasound technology

Brief Snapshot of the Plant

  • Design Capacity: 72,000 PE
  • Actual Capacity: 40,000 PE
  • Biological waste water treatment: P-Elimination, Intermittent denitrification (regulated by Auqualogic, Passavant Intec), Secondary clarification, Downstream P-precipitation (Fe3+), Filtration
  • Sludge treatment: No primary sludge, Thickened waste activated sludge, Co-Fermentate
  • Thickened waste activated sludge: Disc concentrator
  • Anaerobic sludge stabilisation: 1 digester (2.000m, mesophilic), 2 digester(2.000m, used mainly as storage tank), HRT: 22 days
  • Degradation rate of volatile solids (VS): 61% as per cent of dry solids before test phase
  • Digested sludge dewatering: Chamber filter press
  • Sludge disposal: Agriculture

 

Objective of the ultrasound disintegration system

  • Combat foaming sludge in the digester by destroying filamentous microorganisms
  • Fail-free digester performance and trouble-free biogas utilization
  • Increase volatile solids degradation

 

Preliminary trial of the ultrasound disintegration system

  • Test phase of three months (September - November 2004)
  • Total TWAS flow was treated with 1 ULTRAWAVES US unit 5 kW

 

Current WWTP Meldorf Sludge Flow Sheet

 

Results of the trial

  • Combat foaming sludge in digester
    - Foaming was stopped shortly after implementation of the ultrasound system
  • Fail-free performance and trouble-free biogas utilization
    - Continuous addition of co-fermentate is possible
    - Trouble-free utilization of increased biogas production
  • Volatile solids degradation
    - Reduction of the volatile solids from 61% to 45%

 

Reduction of volatile solids since implementation of Ultrasound technology

 

Payback time

Based on these results, the payback time for the ultrasound system installation is calculated with 3 years.

 

Full-scale Installation

Since May 2005 the ULTRAWAVES ultrasonic system is implemented and. And since is in operation 24 hours per day.

 

Installed ultrasonic reactor

 


Send mail to webmaster@ultrawaves.co.uk with questions or comments about this web site.